Zero-Touch Provisioning (ZTP) Not Working

From Baranoski.ca
Revision as of 16:38, 19 September 2024 by Casey (talk | contribs)
Jump to navigation Jump to search

If you are monitoring your ZTP server, and you see the file get downloaded, but you get a message like this:

Auto Image Upgrade: Installation of /var/tmp/junos-arm-32-22.3R1-S2.1.tgz image fetched from server 192.168.1.1 through vme failed:[ERROR: Failed to add junos-arm-32-22.3R1-S2.1.tgz]

You need to set an NTP server in your DHCP scope. A Juniper box checks the signatures of the packages it is installing, and if the system clock is too far off, the certificates will not be valid.