Zero-Touch Provisioning (ZTP) Not Working

From Baranoski.ca
Jump to navigation Jump to search

If you are monitoring your Juniper ZTP server, and you see the file get downloaded, but you get a message like this:

Auto Image Upgrade: Installation of /var/tmp/junos-arm-32-22.3R1-S2.1.tgz image fetched from server 192.168.1.1 through vme failed:[ERROR: Failed to add junos-arm-32-22.3R1-S2.1.tgz]

You need to set an NTP server in your DHCP scope. A Juniper box checks the signatures of the packages it is installing, and if the system clock is too far off, the certificates will not be valid.